Physical Specifications |
Measuring Capacities |
Other |
LengthVariable, based on custom frame design |
Minimum Object Size Non-LFT Version (L x W x H)2 x 2 x 2 in (50 x 50 x 50 mm)
|
Sensor type Non-LFT VersionSICK VMS-410 |
WidthVariable, based on custom frame design |
Minimum Object Size LFT Version (L x W x H)3 x 3 x 2.4 (76 x 76 x 61 mm)
|
Sensory type LFT VersionSICK VMS-510 |
HeightVariable, based on custom frame design |
Maximum Object Size LFT Non-LFT Versions (L x W x H)60 x 48 x 36 in (1524 x 1220 x 914 mm) 102 x 48 x 36 in (2590 x 1220 x 914 mm)
|
Optical indicators6 LEDS per sensor |
WeightApproximately 5 lbs (2.3 kg) per sensor |
Measurement increment Non-LFT Version (L x W x H)Up to 393.7 fpm (2 mps); 0.2 in (5 mm); 394-600 fpm (2-3.05 mps); 0.4 x 0.4 x 0.2 in (10 x 10 x 5 mm)
|
Host interfacesRS-232 (Optional: RS-422, Ethernet, Profibus, Devicenet)
|
|
Measurement increment LFT Version (L x W x H)0.25 x 0.25 x 0.2 in (6 x 6 x 5 mm)
|
Laser Diode (Wavelength)Visible light (650 nm) |
|
Minimum conveyor speed Non-LFT Version10 fmp (0.05 mps) |
Laser PowerMax. 7.5 mW |
|
Minimum conveyor speed LFT Version50 fpm (0.25 mps) |
Laser Class of the DeviceClass 2 (complies with 21 CFR 1040.10 with exception of the deviations per Laster Notice #50, 07/26/2001)
|
|
Maximum conveyor speed LFT and Non-LFT
Version600 fpm (3.05 mps) |
Enclosure Rating/Protection ClassIP 20 (according to DIN 40050); with plug cover IP 65
|
|
Object interval LFT and Non=LFT VersionGreater than or equal to 2 in (50 mm)
|
HousingAluminum die-cast |
|
Detectable Object Shape/ColorCuboidal/Limitations with some dark colors
|
Output data Non-LFT
VersionMaximum dimensions (length, width, height) (optional: box volume)
|
|
Useful Field of ViewMaximum 70 degrees |
Output data LFT VersionMaximum dimensions (length, width, height; box volume)
|
|
Object Remission10-200% |
EMS TestIn compliance with EN 61000-6-2:2001, EN 61000-6-4:2001
|
|
|
Operating Voltage/Power Consumption24 V DC +- 15%/max. 50W |
|
|
Vibration Shock TestIn compliance with EN 60068-2-6,-27,-29,-64
|
|
|
Temperature (Operation/Storage)23° to 104° F / -4° to 158° F (-5° to 40° C / -20° to 70° C)
|